Ticket #496 (closed defect: fixed)

Opened 2010-06-03T23:44:25-05:00

Last modified 2010-07-13T16:57:28-05:00

Leica lookup tables not applied when metadata collection disabled

Reported by: curtis Owned by: melissa
Priority: minor Milestone: bio-formats-4.2
Component: bio-formats Severity: serious
Keywords: Cc:
Blocked By: Blocking:

Description

Running showinf with the -nometa flag on data/leica/joel/sequential scan 2/sequential scan 2.lei results in grayscale image planes, rather than channel 1 having a red LUT.

Change History

comment:1 Changed 2010-06-03T23:48:10-05:00 by curtis

When using the -nometa flag, isIndexed also returns false, even though get8BitLookupTable is still non-null.

comment:2 Changed 2010-06-04T10:23:48-05:00 by melissa

(In [6485]) Updated metadata level tests to check for isIndexed mismatches. See #496.

comment:3 Changed 2010-06-04T10:32:41-05:00 by melissa

  • Status changed from new to closed
  • Resolution set to fixed

(In [6486]) Make sure that CoreMetadata.indexed is set correctly, regardless of the metadata level. Closes #496.

comment:4 Changed 2010-07-09T12:55:02-05:00 by melissa

  • Milestone bio-formats-4.2 deleted

Milestone bio-formats-4.2 deleted

comment:5 Changed 2010-07-13T16:57:28-05:00 by melissa

  • Milestone set to bio-formats-4.2