NOTICE! This is a static HTML version of a legacy LOCI Software ticket.

LOCI projects are now located on GitHub. The Bio-Formats project can be found here.

Ticket #620 (closed defect: fixed)

Opened 2010-12-10T04:12:14-06:00

Last modified 2011-02-02T04:45:00-06:00

OpenlabReader thread safety

Reported by: callan Owned by: callan
Priority: major Milestone: bio-formats-4.3
Component: bio-formats Severity: serious
Keywords: Cc: melissa
Blocked By: Blocking:

Description

The OpenlabReader has thread safety issues due to the usage of an internal static PictReader. Examples of the exceptions and issues in:

 http://hudson.openmicroscopy.org.uk/job/LOCI-omero-openbytes/38/artifact/trunk/components/test-suite/test-output/omero-open-bytes/_hudson_test_images_good_liff_DLD1-MT-04_R3D_D3D.liff.html

Change History

comment:1 Changed 2010-12-10T04:15:10-06:00 by callan

(In [7389]) Resolve OpenlabReader thread safety as it applies to the internal static PictReader. (See #620)

comment:2 Changed 2011-02-02T04:45:00-06:00 by curtis

  • Status changed from new to closed
  • Resolution set to fixed

moved to  ome:#4178