NOTICE! This is a static HTML version of a legacy LOCI Software ticket.

LOCI projects are now located on GitHub. The Bio-Formats project can be found here.

Ticket #693 (closed defect: fixed)

Opened 2012-03-30T18:45:58-05:00

Last modified 2012-04-10T11:32:00-05:00

Fitted plot lacking on decay graph sometimes

Reported by: aivar Owned by: aivar
Priority: major Milestone: slimplugin1.0
Component: slim-plugin Severity: serious
Keywords: Cc:
Blocked By: Blocking:

Description

The red fitted line sometimes doesn't show up on the decay graph. The fit does take place as residuals are shown and the fitted parameters are updated in the UI panel.

Change History

comment:1 Changed 2012-04-10T11:32:00-05:00 by aivar

  • Status changed from new to closed
  • Resolution set to fixed

Fixed with #696.

The decay graph has some logic to cut off the fitted graph when the value is above the maximum photon count. Unfortunately some really bad fits were resulting in a horizontal fitted line way above the photon counts. Because of the cut off this manifested as a lack of the fitted line.