NOTICE! This is a static HTML version of a legacy LOCI Software ticket.

LOCI projects are now located on GitHub. The Bio-Formats project can be found here.

Ticket #617 (closed defect: fixed)

Opened 2010-12-07T15:07:40-06:00

Last modified 2010-12-20T15:42:59-06:00

Channel order is reversed in some LSM files

Reported by: melissa Owned by: melissa
Priority: major Milestone: bio-formats-4.3
Component: bio-formats Severity: serious
Keywords: Cc: Jan.Eglinger@…
Blocked By: Blocking:

Description

See file in data/zeiss-lsm/jan-*/. The images are RGB planes, but the red and blue channels are reversed.

Change History

comment:1 Changed 2010-12-07T15:13:12-06:00 by curtis

  • Cc Jan.Eglinger@… added

comment:2 Changed 2010-12-20T15:40:58-06:00 by melissa

(In [7446]) Parse and apply LUTs stored in the 'u32OffsetChannelColors' block. See #617.

comment:3 Changed 2010-12-20T15:42:59-06:00 by melissa

  • Status changed from new to closed
  • Resolution set to fixed

r7446 fixes the channel coloring. However, this data will not display correctly in Fiji/ImageJ because of #612.