NOTICE! This is a static HTML version of a legacy LOCI Software ticket.

LOCI projects are now located on GitHub. The Bio-Formats project can be found here.

Ticket #711 (closed defect: fixed)

Opened 2012-06-11T15:51:49-05:00

Last modified 2012-06-15T18:43:45-05:00

Bi-exponential fit results don't agree with TRI2

Reported by: aivar Owned by: aivar
Priority: major Milestone: slimplugin1.1
Component: slim-plugin Severity: serious
Keywords: Cc:
Blocked By: Blocking: #674

Description

Using same RLD+LMA fit as #697, (146, 230) of 100611-YG-256.sdt, Gaussian noise:

Single exponential results agree, but double exponential differ:

TRI2: A1 73.24 T1 2.09 A2 3.87 T2 1.77 Z 0.95 X2 0.852904 SLIM Plugin: A1 87.62966 T1 1.911789 A2 0.69900435 T2 0.19606116 Z 1.1207043 X2 0.87658066

Change History

comment:1 Changed 2012-06-11T16:01:34-05:00 by aivar

  • Status changed from new to assigned
  • Component changed from build to slim-plugin

comment:2 Changed 2012-06-15T18:43:45-05:00 by aivar

  • Status changed from assigned to closed
  • Resolution set to fixed

Results now in agreement.